位置:成果数据库 > 期刊 > 期刊详情页
动态轮廓眼压计在正常眼压性青光眼及原发性开角型青光眼的应用研究
  • ISSN号:1672-5123
  • 期刊名称:《国际眼科杂志》
  • 时间:0
  • 分类:R775.2[医药卫生—眼科;医药卫生—临床医学]
  • 作者机构:[1]中国广东省佛山市第二人民医院眼科中心,528000
  • 相关基金:广东省佛山市卫生局医学科研立项(No.2012094)
中文摘要:

目的:应用动态轮廓眼压计( dynamic contour tonometer , DCT)测量正常眼压性青光眼( normal tension glaucoma , NTG)及原发性开角型青光眼( primary open angle glaucoma , POAG)患者的眼压( intraocular pressure , IOP)及眼脉动幅度值( ocular pulse amplitude , OPA),并探讨影响OPA测量值的相关因素。 方法:选取NTG患者20例,POAG患者21例及正常对照组各20例,应用Goldmann压平眼压( Goldmann applanation tonometer, GAT)及DCT测量IOP,同时测量了中央角膜厚度(central corneal thickness,CCT)、眼轴(axial length, AL)、心率( heart rate , HR )、收缩压( systolic blood pressure , SBP)、舒张压( diastolic blood pressure ,DBP)等指标,并探讨GAT,DCT两种眼压计测量的相关性,进而分析OPA测量值的影响因素。 结果:三组被检者的IOP,OPA,SBP 及DBP差异均有统计学意义(P<0.05),而CCT,AL及HR差异无统计学意义(P>0.05)。其中OPA值NTG组为(1.7±0.9)mmHg,POAG组为(2.8±0.7)mmHg,正常对照组为(2.4±0.6)mmHg;NTG组与POAG组比较( P=0.001),与正常对照组比较( P=0.005)差异均有统计学意义,POAG组与正常对照组比较(P=0.502)差异无统计学意义;OPA值与IOP,HR及CCT无相关性(P>0.05),与AL,SBP及DBP具有一定的相关性(P<0.05)。 结论:NTG患者与POAG患者及正常人的OPA值存在差异,同时OPA值受AL及SBP及DBP影响。

英文摘要:

AIM: To survey the application of dynamic contour tonometer ( DCT ) in normal tension glaucoma ( NTG ) patients, primary open angle glaucoma(POAG) patients and healthy controls. And to analyze the factors that influence the ocular pulse amplitude ( OPA) . METHODS: In this case-control study, twenty NTG patients, twenty-one POAG patients and twenty health people were included in the study.Intraocular pressure ( IOP) was measured in each group with GAT and DCT. Correlation between the value of IOP measured with DCT and GAT were analyzed. Meanwhile, central corneal thickness ( CCT ) , axial length ( AL ) , systolic blood pressure(SBP), diastolic blood pressure(DBP) and heart rate( HR) were also measured to evaluate the influencing factor of OPA. RESULTS: There were significant statistical differences of IOP, OPA, SBP and DBP among NTG patients, POAG patients and healthy controls.There were no significant statistical differences of CCT, AL and HR among those subjects.The OPA were 1.7 ±0.9mmHg in NTG patients, 2.8 ±0.7mmHg in POAG patients and 2.4 ±0.6mmHg in normal controls. There was no significant statistical difference of OPA between POAG patients and normal controls(P=0.502), whereas significant statistical difference of OPA between POAG patients and NTG patients (P=0.001) was observed. Significant statistical difference of OPA between NTG patients and normal controls(P=0.005) was detected. The results of Pearson correlation analysis showed that there was significant correlation between OPA with AL, SBP and DBP ( P〈0.05 ).No significant correlation was found between OPA with IOP, HR and CCT(P〉0.05). CONCLUSION: There are differences of OPA among NTG patients, PAOG patients and normal controls.And OPA is influenced by AL, SBP and DBP.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《国际眼科杂志》
  • 中国科技核心期刊
  • 主管单位:中国陕西省卫生和计划生育委员会
  • 主办单位:中华医学会西安分会
  • 主编:惠延年
  • 地址:中国西安友谊东路269号
  • 邮编:710054
  • 邮箱:IJO2000@126.com;IJO.2000@163.com
  • 电话:029-85263940
  • 国际标准刊号:ISSN:1672-5123
  • 国内统一刊号:ISSN:61-1419/R
  • 邮发代号:52-239
  • 获奖情况:
  • 2000年被美国中华医学会评为优秀期刊
  • 国内外数据库收录:
  • 美国化学文摘(网络版),波兰哥白尼索引,荷兰文摘与引文数据库,荷兰医学文摘,中国中国科技核心期刊,瑞典开放获取期刊指南
  • 被引量:22343