以BPA数据为基础,根据相应的电源规划、电网规划和负荷预测得到的2015年浙江电网数据模型,研究按照规划特高压线路接入后负荷模型对浙江电网暂态稳定性分析的影响,并提出了相应的负荷模型选择建议,为特高压输电互联后的安全稳定研究做技术储备。
The Zhejiang Grid data model in 2015 is obtained according to the corresponding power source planning,grid planning and load forecasting based on BPA data.Then the paper analyses the impact of the load model on the transient stability analysis of Zhejiang Grid after the ultra-high voltage lines are connected according to the planning.The corresponding suggestions for selecting the load model are proposed,which may serve as technical references for further research of security and stability of power grid after the interconnection of ultra-high voltage power transmission lines.