位置:成果数据库 > 期刊 > 期刊详情页
Lateral Flow Immunoassay for Quantitative Detection of Ractopamine in Swine Urine
  • ISSN号:0895-3988
  • 期刊名称:Biomedical and Environmental Sciences
  • 时间:2014
  • 页码:134-137
  • 分类:X713[环境科学与工程—环境工程] S965.112[农业科学—水产养殖;农业科学—水产科学]
  • 作者机构:[1]State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, Jiangxi, China, [2]Key Laboratory of Functional Small Organic Molecule, Ministry of Education, Jiangxi Normal University, Nanchang 330022,Jiangxi, China, [3]Wuxi Zodoboer Biotech. Co., Ltd., Wuxi 214174, Jiangsu, China
  • 相关基金:This work was supported by the national science and technology support program in the 12th Five Year Plan (2011BAK10B04 and 2011BAK10B01). the national natural science foundation of China (Grant No. 31160323) and the research program of the state key laboratory of food science and technology, Nanchang University (SKLF-ZZB-201306).
  • 相关项目:建立直接竞争无毒ELISA体系检测食用植物油中苯并芘的方法学研究
中文摘要:

<正>A strip reader based lateral flow immunoassay(LFIA)was established for the rapid and quantitative detection of ractopamine(RAC)in swine urine.The ratio of the optical densities(ODs)of the test line(AT)to that of the control line(AC)was used to effectively minimize interference among strips and sample variations.The linear range for the quantitative detection of RAC was0.2 ng/mL to 3.5 ng/mL with a median inhibitory concentration(IC50)of 0.59±0.06 ng/mL.The limit of detection(LOD)of the LFIA was 0.13 ng/mL.The intra-assay recovery rates were 92.97%,97.25%,and 107.41%,whereas the inter-assay rates were80.07%,108.17%,and 93.7%,respectively.

英文摘要:

A strip reader based lateral flow immunoassay (LFIA) was established for the rapid and quantitative detection of ractopamine (RAC) in swine urine. The ratio of the optical densities (ODs) of the test line (AT) to that of the control line (Ac) was used to effectively minimize interference among strips and sample variations. The linear range for the quantitative detection of RAC was 0.2 ng/mL to 3.5 ng/mL with a median inhibitory concentration (IC50) of 0.59+0.06 ng/mL. The limit of detection (LOD) of the LFIA was 0.13 ng/mL. The intra-assay recovery rates were 92.97%, 97.25%, and 107.41%, whereas the inter-assay rates were 80.07%, 108.17%, and 93.7%, respectively.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《生物医学与环境科学:英文版》
  • 主管单位:卫生部
  • 主办单位:中国疾病预防控制中心
  • 主编:陈春明
  • 地址:北京昌平区昌百路155号中国CDC
  • 邮编:102206
  • 邮箱:bes@chinacdc.cn
  • 电话:010-58900401 58900445传
  • 国际标准刊号:ISSN:0895-3988
  • 国内统一刊号:ISSN:11-2816/Q
  • 邮发代号:
  • 获奖情况:
  • 首届国家优秀期刊三等奖,第三届中国出版政府奖提名奖
  • 国内外数据库收录:
  • 美国化学文摘(网络版),英国农业与生物科学研究中心文摘,荷兰文摘与引文数据库,美国生物医学检索系统,美国科学引文索引(扩展库),美国生物科学数据库,日本日本科学技术振兴机构数据库
  • 被引量:330